Home Blog Thermal Expansion of Metals: Formula, Clearance and Assembly Examples

Thermal Expansion of Metals: Formula, Clearance and Assembly Examples

Release Time: 2026-11-17

Thermal expansion is a change in size caused by a temperature change. For a freely expanding metal over an interval where a constant coefficient is suitable, estimate linear change with ΔL = αL0ΔT. In an assembly, calculate the movement of both mating parts. A pin getting larger does not automatically mean its fit becomes tighter: the hole changes too, and the two parts may have different temperatures.

The practical question is how much clearance or interference remains under the relevant conditions. The worked examples below show the arithmetic using assumed inputs. They are not grade-specific material data, installation instructions or acceptance limits for an actual assembly.

Thermal expansion starts with a temperature interval

Record an initial temperature and a final temperature before selecting a coefficient. A statement such as “the assembly runs at 80°C” does not yet define the change. A dimension referenced at 20°C and one measured at 40°C have different starting conditions, even when both parts later reach the same operating temperature.

In the linear approximation, L0 is the starting length, α is the coefficient of linear thermal expansion, and ΔT is final temperature minus initial temperature. A positive coefficient and a positive temperature change give an increase in free length. Keep the sign when evaluating cooling rather than inserting an absolute temperature difference.

OpenStax describes this as an approximation and notes that the coefficient can vary with temperature. For engineering selection, use data appropriate to the identified material and the interval being evaluated. A handbook heading such as “steel” does not establish a contractual coefficient for every steel grade, condition and temperature range.

Build a small input record before opening a calculator: part identifier, material designation, reference dimension, reference temperature, proposed final temperature, coefficient source and whether the part can expand freely. Mark each assumption as an assumption. This makes it possible to replace preliminary inputs with drawing or material data without losing track of what changed.

For a mating pair, create one record per part. A shared ambient temperature is not proof that both components have the same material temperature during operation. If that temperature is unknown, identify the uncertainty and examine plausible conditions rather than hiding it behind one convenient average.

Calculate a length change with consistent units

Multiply a starting dimension by the fractional expansion over the temperature interval. If the dimension is entered in millimetres, the calculated change is in millimetres. A coefficient expressed per kelvin works with a temperature difference in kelvins; a difference of one kelvin has the same magnitude as a difference of one degree Celsius.

Take an assumed coefficient of 12 × 10−6/K, an initial length of 100 mm and a rise of 60 K. The estimated free change is:

ΔL = 12 × 10−6 × 100 × 60 = 0.072 mm.

The estimated final length is 100.072 mm. The coefficient in this exercise is an assumed constant, not a guaranteed value for a named grade. For a real part, replace it with an appropriate material value and verify that the approximation is suitable over the selected range.

Check the order of magnitude independently. Here αΔT is 0.00072, so the change is a small fraction of the starting length. Multiplying that fraction by 100 mm gives 0.072 mm, or 72 µm. Writing the result in both units helps reveal a misplaced decimal point when the drawing tolerance is expressed in micrometres.

Keep the change and final dimension in separate fields. Entering 0.072 mm into a field intended for the final length creates a very different geometric model. Preserve a few extra digits during intermediate calculations, then report only precision justified by the input data. A calculator displaying many decimals does not improve the certainty of an assumed coefficient or an estimated component temperature.

Why a heated hole can become larger

A hole grows when the surrounding plate undergoes free, uniform expansion with a positive coefficient. The material does not simply expand inward to fill the opening. One way to understand the geometry is to imagine a matching piece placed back into the hole: under the same unconstrained expansion, that piece and the opening would grow together.

Exaggerated schematic showing a larger plate outline and larger hole after free uniform heating
Free, uniform expansion increases the plate’s outside dimensions and its hole. Dashed lines show the original boundaries; the change is exaggerated for explanation.

For a diameter calculation, apply the linear relation to the original hole diameter. Do not apply a volume-expansion coefficient to a linear diameter. Keep the same dimension type throughout the calculation so that the expanded hole can be compared directly with the expanded pin.

The illustration deliberately describes a free plate. A plate clamped into a structure, heated unevenly or already contacting a pin can behave differently because displacement is constrained and mechanical interaction must be considered. The free-hole calculation is a useful starting model, not a universal prediction for every installed bore.

That distinction changes how a buyer should frame an enquiry. “Will heating make the hole larger?” is a geometry question with a simple answer under stated assumptions. “Will this assembled part release at a given temperature?” also depends on the mating part, constraints, contact and temperature distribution. Provide those details before requesting a manufacturing or installation recommendation.

If a sketch includes more than one hole, also identify which feature controls the assembly. A calculation for a bore diameter does not automatically evaluate the location of that bore relative to another datum. Keep size change and positional relationships as separate questions in the design review.

Calculate clearance for a pin and a hole

Diametral clearance is hole diameter minus pin diameter. Estimate each diameter at its own temperature, then subtract. For an initial common reference temperature, the free-expansion model is:

C = H0(1 + αhΔTh) − P0(1 + αpΔTp).

Assume an initial hole diameter of 10.020 mm and pin diameter of 10.000 mm. Initial diametral clearance is 0.020 mm. Assign hypothetical constant coefficients of 23 × 10−6/K to the hole material and 12 × 10−6/K to the pin material. These are exercise inputs, not specifications for particular alloys.

If both rise by 60 K, the hole becomes 10.0338276 mm and the pin becomes 10.0072 mm. Their estimated clearance is 0.0266276 mm, approximately 0.0266 mm. Both dimensions increased, but the hole increased more in this model, so clearance increased.

If both instead cool by 40 K from the reference condition, the estimated hole is 10.0107816 mm and the pin is 9.9952 mm. Clearance is 0.0155816 mm, approximately 0.0156 mm. The sign of the temperature change produces the reduction; it should not be corrected back to a positive value.

These calculations describe nominal free geometry. They do not include contact deformation, coatings or a required operating-clearance limit. If the calculated difference becomes negative, the free dimensions predict overlap; a contact or interference analysis is then needed. The existing dowel-pin press-fit guide addresses the separate fit and installation discussion.

Combine temperature with dimensional tolerances

A calculation using nominal diameters describes one geometric case. A tolerance review asks what happens across the allowed dimensions and relevant thermal states. Preserve that distinction when presenting results to a supplier: a nominal clearance is not necessarily the minimum available clearance.

Within the simple free model, evaluate a smaller allowed hole with a larger allowed pin when investigating a potential low-clearance condition. Evaluate the opposite dimensional combination for a potential high-clearance condition. Temperature cases must come from the assembly’s actual operating possibilities, including whether the components can reach different temperatures.

Review case Dimensional inputs Temperature question
Reference fit Specified reference dimensions and limits At what temperature are they defined?
Potential minimum clearance Smaller hole and larger pin within permitted limits Which realistic temperature pairing reduces the difference?
Potential maximum clearance Larger hole and smaller pin within permitted limits Which realistic temperature pairing increases the difference?
Transient state Relevant dimensions of both components Can one component change temperature before the other?

This worksheet organizes a review; it does not select acceptable values. The required clearance, interference or positional performance must come from the reviewed design. Where coefficient uncertainty matters, include justified coefficient limits rather than presenting one approximate value as exact.

Keep a separate result column for each case, followed by an acceptance reference. That makes it clear whether a result has merely been calculated or has also been checked against a drawing requirement. If a necessary temperature combination has not been established, label the case unresolved. A completed arithmetic sheet should not conceal an incomplete operating specification.

Separate free movement from restraint and gradients

The free-expansion equation predicts how a dimension would change without the relevant mechanical restraint. If the structure prevents that movement, the question becomes one of displacement compatibility and stress. The DOE materials-science handbook distinguishes free expansion from constrained thermal behavior and discusses nonuniform heating as a source of thermal stress.

A simple thought experiment shows why the distinction matters. A bar lying freely on a bench can lengthen as its temperature rises. Put the same bar between boundaries that prevent that movement, and its freely calculated increase is no longer the actual available motion. The missing movement must be considered together with the stiffness and response of the bar, supports and interfaces.

A pin in contact with its bore introduces a related issue. Once free dimensions predict overlap, continuing to subtract diameters does not calculate contact pressure or installation force. Those quantities require additional material and geometric assumptions. Do not interpret a negative clearance number as a complete press-fit design.

Temperature gradients also weaken the single-temperature model. A component with one region warmer than another is not represented by one uniform expansion factor. Before requesting a more detailed analysis, identify the temperature information actually available: measured locations, steady operation, warm-up or cool-down, and any part of the assembly held near a different temperature.

Use the free calculation to locate the question that needs deeper review. It can show that a dimensional difference is sensitive to a proposed condition. It cannot, by itself, establish stress, distortion, fatigue life or a safe heating procedure. Provide the calculated assumptions and the unresolved constraint or gradient explicitly so that the next engineering review starts from the correct problem.

Measure parts at a known reference condition

Record the temperature basis of a dimension before deciding that a warm or cold measurement disagrees with the drawing. NPL’s dimensional-measurement guide identifies 20°C as the conventional reference temperature and discusses differences between instrument and workpiece temperatures. The relevant drawing and inspection agreement should make the reference condition clear.

A hypothetical inspection disagreement illustrates the need for that record. A supplier measures a pin after it has stabilized with its instrument; a buyer measures the received part under a different thermal condition. Comparing the last displayed digit without checking the conditions can turn a temperature question into an apparent material or machining problem.

Retain the raw reading, instrument identity, workpiece temperature information and measurement conditions. If a correction is applied, keep its calculation separate from the original reading and record the coefficient used. A corrected value with no retained starting information is difficult for either party to reproduce.

Do not assume that an instrument’s electronic display automatically compensates for every temperature effect. Determine what its specified compensation, if any, actually covers. The part and the instrument are separate objects; their temperatures and expansion behavior need not match merely because they are in the same room.

For an acceptance disagreement, agree the comparison method before repeating the measurement. Specify how the parts and instruments will reach the required condition and how results will be recorded. The purpose is a reproducible comparison, not a search for the room condition that gives the most favorable number. Keep dimensional acceptance separate from a later calculation of the same part’s size in service.

Give a supplier the thermal assembly requirements

A thermal assembly enquiry needs the mating parts and their operating conditions, not just the pin diameter. Supply an assembly drawing or a clear section sketch that identifies the relevant interfaces and constraints. Eugene’s verified product scope includes locating pins, but an application-specific fit still needs the actual drawing and material requirements.

Provide the material designation of each mating component, their reference dimensions and tolerances, the reference temperature, and the temperatures relevant to assembly and service. Distinguish a measured operating temperature from a preliminary assumption. If the pin and housing can experience different temperatures, provide that relationship rather than one shared maximum.

State the required outcome. Is the concern maintaining clearance, preserving positional control, avoiding an unintended interference condition or understanding a temperature-related inspection disagreement? Each question needs a different acceptance reference. A supplier cannot infer it reliably from a sentence saying “suitable for high temperature.”

For an OEM drawing and material enquiry, include the calculation sheet with its assumptions visible. Ask the supplier which proposed material and delivery-condition details it can confirm and which application decisions require further review. Keep the supplier’s confirmation tied to the quoted item rather than treating a general product listing as approval of the whole assembly.

The useful deliverable is a shared record of dimensions, materials, temperatures, constraints and required fit behavior. With those inputs identified, the simple expansion calculation becomes a transparent first estimate. Where it is insufficient, the same record shows exactly which additional measurement, material data or assembly analysis is needed.

References

OpenStax University Physics: thermal expansion and the behavior of holes

NPL Good Practice Guide 40: callipers, micrometers and temperature effects

US Department of Energy: Materials Science Volume 2, thermal stress fundamentals