Home Blog Concentricity Explained: Coaxiality, Runout and Inspection

Concentricity Explained: Coaxiality, Runout and Inspection

Release Time: 2026-10-31

The basic concentricity definition is a shared center between features; formal drawing requirements are more specific. On an engineering drawing, however, its exact meaning depends on the specified tolerancing standard and edition. It must not automatically be treated as coaxiality or a dial-indicator runout reading. Identify the controlled geometry, datum and applicable rules before selecting an inspection method or accepting a reported value.

Concentricity definition: centers and axes

Two circles can have the same center while having different diameters. That is the basic geometric idea of concentricity. For cylindrical features, the relationship extends into questions about centers at different sections and the axes derived from those features.

A diameter measurement answers a different question. Two features can each meet their size requirements without establishing the required relationship between them. If alignment matters to assembly or rotation, the drawing must communicate that relationship as well as the sizes.

Formal GD&T definitions are more specific than the everyday word. Avoid converting a note such as “keep concentric” into a numerical inspection requirement without clarification. The buyer and supplier need to know which feature is controlled and relative to what datum.

Separate concentricity from runout

Runout concerns surface variation as a part rotates about the specified datum axis. A dial indicator contacts a surface, so the reading can reflect surface form and its relationship to the rotation axis. It does not automatically isolate a center-location requirement.

A derived-center evaluation asks a different geometric question. Consequently, a low indicator reading should not be accepted as proof of every requirement described informally as concentricity. The drawing’s control determines the required evaluation.

Choose the control from the functional need. Is the engineer trying to locate an axis, limit surface variation during rotation or satisfy a legacy median-point requirement? State that need before asking the inspection team to choose between a rotational setup and a coordinate-based evaluation.

Shared and offset centers alongside a separate indicator contacting a rotating surface
Conceptual center relationships and a surface-indicator setup. The indicator illustration does not establish a concentricity acceptance method.

Check the standard and drawing edition

ASME Y14.5-2018 removed the concentricity and symmetry controls. NIST’s GD&T teaching material distinguishes using position to control a feature’s axis from using runout to control its surface. These controls serve different functional purposes; they are not interchangeable names.

A legacy drawing remains tied to its stated requirements until the responsible design authority changes it. Do not silently replace an older concentricity callout with runout simply because a shop can measure runout more readily.

Likewise, do not transfer a definition from an ISO-oriented guide into an ASME drawing without checking the applicable rules. Resolve the standard and edition before comparing acceptance values or programming a measurement routine.

Agree how the requirement will be measured

Describe the datum feature, controlled feature, evaluated extent and required result. Ask the inspection provider to explain how the setup establishes the datum and how the reported value corresponds to the drawing requirement.

For a coordinate measurement, agree the relevant sampling and evaluation approach where these affect acceptance. For a rotational measurement, identify the support arrangement, contact location and evaluated surface. Naming an instrument alone does not define the complete method.

Keep the method with the report, particularly when customer and supplier results differ. Compare setups and evaluated geometry before assuming one instrument is wrong. A disagreement can concern the interpretation of the requirement rather than only measurement repeatability.

Resolve a locating-part RFQ

Supply the drawing revision, governing tolerancing standard, datum scheme, size requirements and geometric controls. Identify the feature that actually locates the assembly. If a note is ambiguous, ask the design owner to clarify it before sample production.

For a custom locating part, Eugene’s drawing-based fastener service is an appropriate inquiry route. Include the requested inspection evidence and ask the quotation to identify unresolved geometric requirements. A product-family name or nominal diameter cannot substitute for a controlled drawing and agreed evaluation method.

References

ZEISS: concentricity and center-location concepts; NIST and UNC Charlotte: GD&T fundamentals, including ASME Y14.5-2018 changes.